Overview
A small blower used to pull air out of a cabinet or a compartment through a defined outlet. Because the discharge is directional, it can be connected to a short duct or aimed at a vent, which a panel-mounted axial fan cannot do.
The range covers several sizes with sleeve or ball bearings. It is intended for short extraction paths: once the duct gets long or narrow, the pressure demand moves beyond what this class can hold.
Where it fits
- Small cabinet exhaust
- Equipment compartments with a vent stub
- Local extraction inside machines
- Electronics enclosures with a filtered intake
Specifications
| Model | Bearing System | Voltage (V) | Voltage Range (V) | Current (A) | Power (W) | Speed (RPM) | Moise (dBA) | Air Flow | Static Pressure | Weight (G) | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| m3/h | CFM | Pa | mmH2O | |||||||||
| TD602512L | Sleeve/Ball | 12VDC | 6-13.2 | 0.04 | 0.48 | 3000 | 31.1 | 8.3 | 4.9 | 73.5 | 7.5 | 48 |
| TD602512M | Sleeve/Ball | 12VDC | 6-13.2 | 0.13 | 1.56 | 4500 | 40.8 | 12.4 | 7.3 | 164.6 | 16.8 | 48 |
| TD602512H | Sleeve/Ball | 12VDC | 6-13.2 | 0.49 | 5.88 | 6000 | 47.8 | 16.5 | 9.7 | 292.0 | 29.8 | 48 |
| TD602524L | Sleeve/Ball | 24VDC | 12-26.4 | 0.02 | 0.48 | 3000 | 31.1 | 8.3 | 4.9 | 73.5 | 7.5 | 48 |
| TD602524M | Sleeve/Ball | 24VDC | 12-26.4 | 0.09 | 216 | 4500 | 40.8 | 12.4 | 7.3 | 164.6 | 16.8 | 48 |
| TD602524H | Sleeve/Ball | 24VDC | 12-26.4 | 0.18 | 432 | 6000 | 47.8 | 165 | 9.7 | 292.0 | 29.8 | 48 |
Selection and installation notes
Match the intake area to the blower. A restricted intake starves the wheel and raises noise without improving extraction.
If the air carries dust or oil mist, plan cleaning access. A loaded wheel loses balance quickly at small diameters.
Related models
If this frame size or voltage is not the one you need, the Small DC Cooling Blower for Enclosures, the Brushless Silent DC Blower and the DC Blower Fan for Pressure Duty sit in the same range. All 7 models in Small DC Centrifugal Blowers are listed with their airflow and pressure figures. Blade shapes, drive arrangements and casing options are compared in Centrifugal Fan Types: Blades, Drives and Casings.
FAQ
Can it replace a panel fan?
Only where a directional outlet helps. For simple through-panel airflow, an axial fan is usually simpler and quieter.
How long can the duct be?
Short. This class holds limited pressure; long or narrow runs need a larger centrifugal unit.
Is it available in 12 V and 24 V?
Yes, depending on the model. Check the table for the voltage and current of each variant.
Does it include a guard?
The blower is supplied as a unit; guards and inlet screens are selected separately.
Request Quote
Interested in this product? Share your requirements or questions using the form.
-
Your requirements
Include the specifications, options, or quantity you need, if known.
-
Your questions
Ask about product details, availability, or order information.
-
Your contact details
Leave an email address where you can receive a reply.