Double Inlet Centrifugal Fan for Air Handling

Double inlet centrifugal fan that moves high air volume from a narrow housing, for air handling, drying and air curtains.
  • Power: 0.126 W
  • Airflow: 7601300 m³/h
Share to:

Overview

A double inlet fan draws air from both sides of a wide impeller and discharges it through one scroll. Because the air enters twice, the housing can stay narrow while moving a large volume — the reason this shape dominates air handling units.

The range covers several sizes and drive arrangements. Belt drive allows the speed to be trimmed during commissioning, which matters when the duct system is finished after the fan is selected.

Where it fits

  • Air handling units
  • Drying and curing chambers
  • Air curtains
  • Supply and return air plenums

Specifications

Double Inlet Centrifugal Fan for Air Handling — specifications
Model Power-pole number (KW-Pole) Air Flow (m3/h) Pressure (Pa) Model Power-pole number (KW-Pole) Air Flow (m3/h) Pressure (Pa)
2.1 0.12-6C 760~1300 143~154~150 2.5 0.8-4C 2400~4000 422~447~394
0.12-6 760~1300 145~155~151 2.8 0.55-6 2700~3700 297~236
0.18-4 1000~1600 296~315~310 1.1-4 3000~5000 548~452
0.25-4 900~1700 297~310~300 1.1-4C 3000~5000 548~452
0.25-4C 900~1700 295~311~298 1.2-4 4400~6000 533~446
2.15 0.25-4 1000~1800 320~339~335 1.5-4 4500~6100 553~374
0.25-4C 1000~1800 320~339~335 3.0 0.8-6 3200~5000 339~230
0.32-4 1100~2300 280~300~230 1.1-6 4000~6000 290~210
0.32-4C 1100~2300 280~300~230 1.5-4 4000~4800 685~687~652
0.37-4 1300~2500 363~344~367 1.8-4 5000~7000 528~452
0.45-4 1500~2700 352~393 2.2-4 6000~8000 603~403
0.55-4 1700~3000 382~418~395 3.15 0.8-6 3600~5200 379~290
2.15B 0.25-4 1000~1800 320~339~335 1.1-6 4000~6000 358~281
0.25-4C 1000~1800 320~339~335 1.8-4 6000~8000 684~599
0.32-4 1100~2300 280~300~230 2.2-4 6500~8600 700~576
0.32-4C 1100~2300 280~300~230 3.0-4 7000~9500 685~520
0.37-4 1300~2500 363~344~367 3.55 1.5-6 4600~6600 497~506~369
0.45-4 1500~2700 352~393 1.8-6 5500~8000 5500~8000 440~300
0.55-4 1700~3000 382~418~395 3.0-4 7000~9200 845~907
2.25 0.18-6 1000~2300 165~185~178 4.0-4 7000~11000 867~921~898
0.25-6 1100~2600 167~192~82 4.0 1.8-6 6000~7200 619-653
0.32-4 1500~2500 334~357~342 2.2-6 6300~8000 631~656
0.32-4C 1500~2500 334~357~342 3.0-6 7500~11000 659~664~610
0.37-4 1450~2650 370~356~368 4.5 4.0-6 8500~12000 776~840
0.37-4C 1450~2650 370~356~368 5.5-6 10000~16000 864~876~687
0.45-4 1500~2500 370~356~368 7.5-6 12000~18000 870~880~650
0.55-4 1300~3000 382~432~409 5.0 7.5-6 15000~19000 892~938~921
0.55-4C 1300~3000 382~425~410 9.0-6 17000~21000 935~880
2.25B 0.18-6 1000~2300 165~185~178 PQF(C)series leather drive air conditioner fan
0.25-6 1100~2600 167~192~182 Model Air Flow (m3/h) Pressure (Pa)
0.32-4 1500~2500 334~357~342
0.37-4 1450~2650 370~356~368 PQF25O 2200~5300 290~790
0.37-4C 1450~2650 370~356~368 PQF280 2300~7000 290~820
0.45-4 1500~2500 370~356~368 PQF315 2600~8200 300~800
0.55-4 1300~3000 382~432~409 PQF355 2600~15000 350~1090
0.55~4C 1300~3000 382~425~410 PQF400 5000~19000 400~1310
2.25A 0.25-6 1500~2700 202~125 PQF450 7000~23300 335~1140
0.45-4 1650~2600 427~448~432 PQF500 8000~35000 310~1230
0.554 1800-3000 423~449~431 PQF560 14000~40000 480~1500
0.8-4 2400~3600 430~396 PQF630 20000~52000 660~1560
0.55-4C 1800~3000 423~449~431 PQF710 20000~68000 590~1400
0.8-4C 2400~3600 430~396 PQF800 25000~80000 600~1450
2.5 0.25-6 1500~2400 217~234~216 PQF900 30000~92000 600~1340
0.55-4 1700~2700 448~474 PQF1000 55000~110000 680~1400
0.8-4 2400~4000 422~447~394 PQFXXXC
0.55-4C 1700~2700 448~474 PQFXXXE

Selection and installation notes

State the airflow at the external static pressure. A free-air figure is meaningless in air handling, where coils and filters always add resistance.

Check the available width before ordering. The impeller width follows the airflow, and the housing length follows the impeller.

FAQ

Direct drive or belt drive?

Direct drive for a fixed duty and low maintenance; belt drive where the speed has to be adjusted on site.

Can the discharge direction be changed?

On many designs the scroll can be rotated. Confirm before ordering; it is not a site modification on every model.

Is it suitable for dirty air?

Less than a backward-curved fan. The forward-curved wheel collects dust and loses balance.

How do I size the motor?

From the duty point and the fan efficiency, with margin for a system that turns out more restrictive than expected.

Request Quote

Interested in this product? Share your requirements or questions using the form.

  • Your requirements

    Include the specifications, options, or quantity you need, if known.

  • Your questions

    Ask about product details, availability, or order information.

  • Your contact details

    Leave an email address where you can receive a reply.

+86-15058710888 Phone export@wilmall.com E-mail Chat on WhatsApp WhatsApp