Low Noise AC Centrifugal Blower

AC centrifugal blower with a wide, slow wheel for low noise at useful airflow, for air handling and equipment rooms.
  • Voltage: 220380 V
  • Frequency: 50 Hz
  • Power: 1.1–750 W
  • Speed: 2800 rpm
Share to:

Overview

A centrifugal blower designed around noise rather than maximum volume: a wider wheel running slower, with a housing that resists resonance. It suits equipment rooms, air handling and ventilation where the fan is close to occupied space.

Several sizes cover different airflow classes. Selection usually starts with the airflow and the acceptable sound level, then checks the pressure the duct system adds.

Where it fits

  • Air handling and supply units
  • Equipment rooms near work areas
  • Drying and curing chambers
  • Ventilation where noise is regulated

Specifications

Low Noise AC Centrifugal Blower — specifications
Model Power (w) Voltage(V) Rotating speed (r/min) Frequency (Hz) Flow (m3/h) Full pressure(Pa)
DF-1 120W 220/380 2800 50 305 330
DF-2 180W 220/380 2800 50 405 450
DF-3 250W 220/380 2800 50 504 860
DF-4 370W 220/380 2800 50 660 850
DF-5 550W 220/380 2800 50 860 1020
DF-6 750W 220/380 2800 50 1200 1210
DF-7 1.1KW 220/380 2800 50 1900-2700 1380-1240
DF-8 1.5KW 220/380 2800 50 2600-3500 1360-1220
DF-9 2.2KW 220/380 2800 50 3300-4000 1470-1300
DF-10 3.0KW 220/380 2800 50 3900-4600 2050-1860

Selection and installation notes

A slow, wide wheel is quiet at the unit but the duct can still transmit noise. Flexible connectors and a straight discharge section do more than a larger fan.

Check the pressure at the duty point. Low-noise designs often trade pressure for sound, so a restrictive system can move the choice to a different range.

FAQ

How is the noise reduced?

By running a wider wheel slower and stiffening the housing. The result is lower sound pressure at the same airflow class.

Can it be belt driven?

Some sizes are available with belt drive so the speed can be trimmed during commissioning. Confirm per model.

What about pressure?

It holds moderate pressure. For long ducts or dense filters, check the duty point carefully or move to a backward-curved fan.

Is a silencer needed?

Often not at the unit, but the duct may still need one. Plan attenuation on the discharge if the outlet is near occupied space.

Request Quote

Interested in this product? Share your requirements or questions using the form.

  • Your requirements

    Include the specifications, options, or quantity you need, if known.

  • Your questions

    Ask about product details, availability, or order information.

  • Your contact details

    Leave an email address where you can receive a reply.

+86-15058710888 Phone export@wilmall.com E-mail Chat on WhatsApp WhatsApp